VIRTUAL TESTING / CDS WORKBENCH
ASTM D6484 · Open-hole compression
Measures compressive strength of a composite laminate containing an unfilled hole.
CDS sign-in and suitable licensed access may be required.
Recorded instructional case · Workbench captures and saved calculation data, October 2026. This website preview does not run the test.
Specimen & fixture

Calculated assessment
Demand / measured strength
Force magnitude (N)
View plotted values
| Series | Force magnitude (N) | Demand / measured strength |
|---|---|---|
| Open-hole test-data screening | 0 | 0 |
| Open-hole test-data screening | 10 | 0.0005555555555555556 |
| Open-hole test-data screening | 20 | 0.0011111111111111111 |
| Open-hole test-data screening | 30 | 0.0016666666666666668 |
| Open-hole test-data screening | 40 | 0.0022222222222222222 |
| Open-hole test-data screening | 50 | 0.002777777777777778 |
| Open-hole test-data screening | 60 | 0.0033333333333333335 |
| Open-hole test-data screening | 70 | 0.0038888888888888888 |
| Open-hole test-data screening | 80 | 0.0044444444444444444 |
| Open-hole test-data screening | 90 | 0.005 |
| Open-hole test-data screening | 100 | 0.005555555555555556 |
| Open-hole test-data screening | 110 | 0.006111111111111111 |
| Open-hole test-data screening | 120 | 0.006666666666666667 |
| Open-hole test-data screening | 130 | 0.007222222222222222 |
| Open-hole test-data screening | 140 | 0.0077777777777777776 |
| Open-hole test-data screening | 150 | 0.008333333333333333 |
| Open-hole test-data screening | 160 | 0.008888888888888889 |
| Open-hole test-data screening | 170 | 0.009444444444444445 |
| Open-hole test-data screening | 180 | 0.01 |
| Open-hole test-data screening | 190 | 0.010555555555555556 |
| Open-hole test-data screening | 200 | 0.011111111111111112 |
| Open-hole test-data screening | 210 | 0.011666666666666667 |
| Open-hole test-data screening | 220 | 0.012222222222222223 |
| Open-hole test-data screening | 230 | 0.012777777777777779 |
| Open-hole test-data screening | 240 | 0.013333333333333334 |
| Open-hole test-data screening | 250 | 0.013888888888888888 |
| Open-hole test-data screening | 260 | 0.014444444444444444 |
| Open-hole test-data screening | 270 | 0.015 |
| Open-hole test-data screening | 280 | 0.015555555555555555 |
| Open-hole test-data screening | 290 | 0.01611111111111111 |
| Open-hole test-data screening | 300 | 0.016666666666666666 |
| Open-hole test-data screening | 310 | 0.017222222222222222 |
| Open-hole test-data screening | 320 | 0.017777777777777778 |
| Open-hole test-data screening | 330 | 0.018333333333333333 |
| Open-hole test-data screening | 340 | 0.01888888888888889 |
| Open-hole test-data screening | 350 | 0.019444444444444445 |
| Open-hole test-data screening | 360 | 0.02 |
| Open-hole test-data screening | 370 | 0.020555555555555556 |
| Open-hole test-data screening | 380 | 0.021111111111111112 |
| Open-hole test-data screening | 390 | 0.021666666666666667 |
| Open-hole test-data screening | 400 | 0.022222222222222223 |
| Open-hole test-data screening | 410 | 0.02277777777777778 |
| Open-hole test-data screening | 420 | 0.023333333333333334 |
| Open-hole test-data screening | 430 | 0.02388888888888889 |
| Open-hole test-data screening | 440 | 0.024444444444444446 |
| Open-hole test-data screening | 450 | 0.025 |
| Open-hole test-data screening | 460 | 0.025555555555555557 |
| Open-hole test-data screening | 470 | 0.026111111111111113 |
| Open-hole test-data screening | 480 | 0.02666666666666667 |
| Open-hole test-data screening | 490 | 0.02722222222222222 |
| Open-hole test-data screening | 500 | 0.027777777777777776 |
| Open-hole test-data screening | 510 | 0.028333333333333332 |
| Open-hole test-data screening | 520 | 0.028888888888888888 |
| Open-hole test-data screening | 530 | 0.029444444444444443 |
| Open-hole test-data screening | 540 | 0.03 |
| Open-hole test-data screening | 550 | 0.030555555555555555 |
| Open-hole test-data screening | 560 | 0.03111111111111111 |
| Open-hole test-data screening | 570 | 0.03166666666666667 |
| Open-hole test-data screening | 580 | 0.03222222222222222 |
| Open-hole test-data screening | 590 | 0.03277777777777778 |
| Open-hole test-data screening | 600 | 0.03333333333333333 |
| Open-hole test-data screening | 610 | 0.03388888888888889 |
| Open-hole test-data screening | 620 | 0.034444444444444444 |
| Open-hole test-data screening | 630 | 0.035 |
| Open-hole test-data screening | 640 | 0.035555555555555556 |
| Open-hole test-data screening | 650 | 0.03611111111111111 |
| Open-hole test-data screening | 660 | 0.03666666666666667 |
| Open-hole test-data screening | 670 | 0.03722222222222222 |
| Open-hole test-data screening | 680 | 0.03777777777777778 |
| Open-hole test-data screening | 690 | 0.03833333333333333 |
| Open-hole test-data screening | 700 | 0.03888888888888889 |
| Open-hole test-data screening | 710 | 0.03944444444444444 |
| Open-hole test-data screening | 720 | 0.04 |
| Open-hole test-data screening | 730 | 0.04055555555555555 |
| Open-hole test-data screening | 740 | 0.04111111111111111 |
| Open-hole test-data screening | 750 | 0.041666666666666664 |
| Open-hole test-data screening | 760 | 0.042222222222222223 |
| Open-hole test-data screening | 770 | 0.042777777777777776 |
| Open-hole test-data screening | 780 | 0.043333333333333335 |
| Open-hole test-data screening | 790 | 0.04388888888888889 |
| Open-hole test-data screening | 800 | 0.044444444444444446 |
| Open-hole test-data screening | 810 | 0.045 |
| Open-hole test-data screening | 820 | 0.04555555555555556 |
| Open-hole test-data screening | 830 | 0.04611111111111111 |
| Open-hole test-data screening | 840 | 0.04666666666666667 |
| Open-hole test-data screening | 850 | 0.04722222222222222 |
| Open-hole test-data screening | 860 | 0.04777777777777778 |
| Open-hole test-data screening | 870 | 0.04833333333333333 |
| Open-hole test-data screening | 880 | 0.04888888888888889 |
| Open-hole test-data screening | 890 | 0.049444444444444444 |
| Open-hole test-data screening | 900 | 0.05 |
| Open-hole test-data screening | 910 | 0.050555555555555555 |
| Open-hole test-data screening | 920 | 0.051111111111111114 |
| Open-hole test-data screening | 930 | 0.051666666666666666 |
| Open-hole test-data screening | 940 | 0.052222222222222225 |
| Open-hole test-data screening | 950 | 0.05277777777777778 |
| Open-hole test-data screening | 960 | 0.05333333333333334 |
| Open-hole test-data screening | 970 | 0.05388888888888889 |
| Open-hole test-data screening | 980 | 0.05444444444444444 |
| Open-hole test-data screening | 990 | 0.055 |
| Open-hole test-data screening | 1000 | 0.05555555555555555 |
Set up in CDS
- Link the laminate and define the open-hole coupon.
- Enter force magnitude and matched measured OHC strength.
- Calculate gross and net compression magnitudes.
- Review load demand against the gross-area strength.
Inputs for this recorded case
- 150 × 36 × 2 mm
- 16 plies / 2 mm
- Selected force 1000 N
- Explicit source calibration/properties
These are teaching-case inputs, not ASTM-prescribed specimen dimensions or acceptance criteria.
Readout & interpretation
- Gross compression magnitude
- 13.89 MPa
- Net compression magnitude
- 16.67 MPa
- Open-hole demand / measured strength
- 0.05556 —
Measured-data screening. Local buckling, kink bands and hole damage are excluded.
About this ASTM reference
Standard Test Method for Open-Hole Compressive Strength of Polymer Matrix Composite Laminates
Active catalog edition checked October 10, 2026. The official standard defines the physical method; the CDS example below has a narrower modeling scope. Full procedures remain on ASTM’s site.
Find this setup in Workbench
Opens the connected guided study. Select the matching ASTM setup in the Test menu to inspect its fixture.
What this CDS case represents
Read the actual ASTM standard ↗Measured-data screening. Local buckling, kink bands and hole damage are excluded.
This analytical or measured-data model provides its own curves and metrics. Synchronized failure playback is not supported; a mounted fixture view does not imply that contact, crack growth or impact history is solved.
Model basis · equation and interpretation
σgross = P/(wt); σnet = P/[(w − d)t]; demand = σgross/XOHC.
P is compressive force magnitude, w width, t thickness and d hole diameter. XOHC is matched measured gross-section compressive strength. Do not compare net stress with a gross-section allowable. The assessment does not predict compressive notch strength.
Instructional model comparison, not experimental validation or ASTM certification. Physical testing requires the licensed standard and a qualified test program.
